What is electric traction?

Answer: Traction means using the electric power for traction system i.e. for railways, trams, trolleys etc. electric traction means use of the electricity for all these. Now a day, magnetic traction is also used for bullet trains. Basically dc motors are used for electric traction systems. 

How can you start-up the 40w tube lite with 230v AC/DC without using any choke/Coil?

Answer: It's possible by means of Electronic choke. otherwise it's not possible to ionize the particles in tube. light, with normal voltage. 

What is "pu" in electrical engineering?

Answer: Pu stands for per unit and this will be used in power system single line diagram there it is like a huge electrical circuit with no of components (generators, transformers, loads) with different ratings (in MVA and KV). To bring all the ratings into common platform we use pu concept in which, in general largest MVA and KV ratings of the component is considered as base values, then all other component ratings will get back into this basis. Those values are called as pu values. (p.u=actual value/base value). 

Operation carried out in Thermal power station?

Answer:The water is obtained in the boiler and the coal is burnt so that steam is obtained this steam is allowed to hit the turbine , the turbine which is coupled with the generator generates the electricity 

Why link is provided in neutral of an ac circuit and fuse in phase of ac circuit?

Answer:Link is provided at a Neutral common point in the circuit from which various connection are taken for the individual control circuit and so it is given in a link form to withstand high Amps. But in the case of Fuse in the Phase of AC circuit it is designed such that the fuse rating is calculated for the particular circuit (i.e load) only.So if any malfunction happen the fuse connected in the particular control circuit alone will blow off. 

what is the diff. btwn. electronic regulator and ordinary rheostat regulator for fans?

Answer:The difference between the electronic and ordinary regulator is that in electronic reg. power losses are less because as we decrease the speed the electronic reg. give the power needed for that particular speed but in case of ordinary rheostat type reg. the power wastage is same for every speed and no power is saved.In electronic regulator triac is employed for speed control.by varying the firing angle speed is controlled but in rheostatic control resistance is decreased by steps to achievespeed control. 

How tube light circuit is connected and how it works?

Answer:A choke is connected in one end of the tube light and a starter is in series with the circuit. When supply is provided ,the starter will interrupt the supply cycle of AC. Due to the sudden change of supply the chock will generate around 1000volts . This volt will capable of to break the electrons inside the tube to make electron flow. once the current passes through the tube the starter circuit will be out of part. now there is no change of supply causes choke voltage normalized and act as minimize the current. 

whats is MARX CIRCUIT?

Answer:It is used with generators for charging a number of capacitor in parallel and discharging them in series.It is used when voltage required for testing is higher than the available. 

What is encoder, how it function?

Answer:An encoder is a device used to change a signal (such as a bitstream) or data into a code. The code may serve any of a number of purposes such as compressing information for transmission or storage, encrypting or adding redundancies to the input code, or translating from one code to another. This is usually done by means of a programmed algorithm,especially if any part is digital, while most analog encoding is done with analog circuitry. 

What are the advantages of speed controlusing thyristor?

Answer:Advantages :1. Fast Switching Characterstics than Mosfet, BJT, IGBT 2. Low cost 3. Higher Accurate. 

Why Human body feel Electric shock ?? n in an Electric train during running , We did nt feel any Shock ? why? 

Answer:Unfortunately our body is a pretty good conductor of electricity, The golden rule is Current takes the lowest resistant path if you have insulation to our feet as the circuit is not complete (wearing rubber footwear which doing some repairs is advisable as our footwear is a high resistance path not much current flows through our body).The electric train is well insulated from its electrical system. 

what is the principle of motor?

Answer:Whenever a current carrying conductor is placed in an magnetic field it produce turning or twisting movemnt is called as torque. 

why, when birds sit on transmission lines or current wires doesn't get shock?

Answer:Its true that if birds touch the single one line (phase or neutral) they don't get electrical shock... if birds touch 2 lines than the circuit is closed and they get electrical shock.. so if a human touch single one line(phase) then he doesn't get shock if he is in the air (not touching - standing on the ground if he is standing on the ground then touching the line (phase) he will get a shock because the ground on what we standing is like line (ground bed - like neutral)? and in the most of electric lines the neutral is grounded..so that means that human who touch the line closes the circuit between phase and neutral. 

what is meant by armature reaction?

Answer:The effect of armature flu to main flux is called armature reaction. The armature flux may support main flux or opposes main flux. 

what happen if we give 220 volts dc supply to d bulb r tube light?

Answer:Bulbs [devices] for AC are designed to operate such that it offers high impedance to AC supply. Normally they have low resistance. When DC supply is applied, due to low resistance, the current through lamp would be so high that it may damage the bulb element. 

Which motor has high Starting Torque and Staring current DC motor, Induction motor or Synchronous motor? 

Answer:DC Series motor has high starting torque. We can not start the Induction motor and Synchronous motors on load, but can not start the DC series motor without load. 

what is ACSR cable and where we use it?

Answer:ACSR means Aluminium conductor steel reinforced, this conductor is used in transmission & distribution. 

What is vaccum currcuit breaker.define with cause and where be use it Device?

Answer:A breaker is normally used to break a ciruit. while breaking the circuit, the contact terminals will be separated. At the time of seperation an air gap is formed in between the terminals. Due to existing current flow the air in the gap is ionised and results in the arc. various mediums are used to quench this arc in respective CB's. but in VCB the medium is vaccum gas. since the air in the CB is having vaccum pressure the arc formation is interrupted. VCB's can be used upto 11kv. 

What will happen when power factor is leading in distribution of power?

Answer:If their is high power factor, i.e if the power factor is close to one:

1.losses in form of heat will be reduced,

2.cable becomes less bulky and easy to carry, and very

cheap to afford, &

3. it also reduces over heating of tranformers. 

whats the one main difference between UPS & inverter ? And electrical engineering & electronics engineering ? 

Answer:uninterrupt power supply is mainly use for short time . means according to ups VA it gives backup. ups is also two types : on line and offline . online ups having high volt and amp for long time backup with with high dc voltage.but ups start with 12v dc with 7 amp. but inverter is startwith 12v,24,dc to 36v dc and 120amp to 180amp battery with long time backup. 

What is 2 phase motor?

Answer:A two phase motor is a motor with the the starting winding and the running winding have a phase split. e.g;ac servo motor.where the auxiliary winding and the control winding have a phase split of 90 degree. 

Advantages of vvvf drives over non vvvf drives for EOT cranes?

Answer:1.smooth start and stop.

2.no jerking of load.

3.exact posiitoning

4.better protection for motor.

5.high/low speed selection.

6.reliability of break shoe.

7.programmable break control.

8.easy circutry

9.reduction in controls

10.increases motor life

Source: Contents are provided by Technicalsymposium Google Group Members. 
Disclaimer: All the above contents are provided by technicalsymposium.com Google Group members. 
Further, this content is not intended to be used for commercial purpose. Technicalsymposium.com is not liable/responsible for any copyright issues.


Download All Technical Interview Materials